Weintek MT8071iE & YASKAWA V1000 “Modbus-RTU” Tutorial

Yaskawa V1000 inverter is an extremely famous inverter in the world, this is a multi-purpose inverter with many outstanding advantages.

Today thelivingchristmascompany.com would like to guide you to use HMI Weintek MT8071iE to connect Yaskawa V1000 inverter control via Modbus RTU communication

Wiring Diagram MT8071iE & V1000 VFD

Inverter Parameter Configuration

Here are the basic communication parameters we need to set

Command Data

+ Control Run (0001H)

  • Set 0001H = “1” >>> Forward Run
  • Set 0001H = “2” >>> Reverse Run
  • Set 0001H = “0” >>> Stop

+ Set Frequency: (0002H)

Monitor Data

+ 0024H = 36 (dec)

+ 0025H = 37 (dec)

+ 0026H =38 (dec)

Weintek MT8071iE . Communication Configuration

We choose communication for MT8071ie according to inverter with parameters (9600/8/1/E)

Screen Design

 When using Weintek HMI for Modbus-RTU communication, we have to add the register address 1 unit.

For example in this project the frequency register is 0002H + 1 = 0003H

======

Detailed programming instructions

+ Forward Button

+ Reverse Button

+ Stop Button

+ Setting Frequency

+ Output Frequency

+ Output Voltage

+ Output Current

Detailed Instruction Video

======

Software and supporting documentation

+ EasyBuilder-Pro for HMI Weintek MT8071iE

(password: thelivingchristmascompany.com)

If you have any questions, please comment below the article, thelivingchristmascompany.com will answer as soon as I read it.